Precautions for installation and use of self limiting heat tracing tape
1Self limiting tropical zoneAfter measuring the appropriate length for use, leave an extra 20 centimeters for wiring.
2. After cutting the blind end of the self limiting heat tracing strip, the matching protective shell should be installed, and it is important to note that the two wire cores cannot overlap. The blind end should be treated with sealant and insulating cloth.
3. Be sure to avoid using self limiting heat tracing strips with damaged surfaces, pay attention to waterproofing, and prevent any potential hazards.
4. Generally speaking, the length of a single self limiting temperature tracing tape with a rated voltage of 12V should be less than 30 meters, and in order to achieve insulation effect, the tracing tape should be tightly wrapped around the water pipe.
Prev: What pipelines are suitable for electric heat tracing
Next: Suitable occasions for constant power electric heating belts
Related News
- What is the difference between a constant power electric heating belt and a self limiting temperatur
- How to standardize the use of pipeline electric heating belts for safer safety
- Reasons why constant power electric heating belts may experience melting problems during use
- Electric heat tracing manufacturers remind everyone to cut off the power and stop using the electric
- The main purpose of MI heating cable
- Requirements for the use of MI heating cables
- Are there any requirements for using electric heat tracing tape in industrial chemical materials
- Possible issues that may arise during the use of electric heating belts
- Always remember the working standards for using electric heat tracing
- Electric heat tracing can easily solve pipeline freezing caused by asphalt residue