Precautions for installation and use of self limiting heat tracing tape
1Self limiting tropical zoneAfter measuring the appropriate length for use, leave an extra 20 centimeters for wiring.
2. After cutting the blind end of the self limiting heat tracing strip, the matching protective shell should be installed, and it is important to note that the two wire cores cannot overlap. The blind end should be treated with sealant and insulating cloth.
3. Be sure to avoid using self limiting heat tracing strips with damaged surfaces, pay attention to waterproofing, and prevent any potential hazards.
4. Generally speaking, the length of a single self limiting temperature tracing tape with a rated voltage of 12V should be less than 30 meters, and in order to achieve insulation effect, the tracing tape should be tightly wrapped around the water pipe.
Prev: What pipelines are suitable for electric heat tracing
Next: Suitable occasions for constant power electric heating belts
Related News
- Precautions for using explosion-proof electric heating belts
- Advantages of MI heating cable
- Guide everyone to understand the working standards for using electric heat tracing
- Methods for preventing freezing of pipelines in winter
- Do you want to know why the series constant power electric heating strip cannot be cut arbitrarily
- Electric heat tracing is closely related to people's lives
- Electric heat tracing manufacturers will introduce the working principle of electric heat tracing be
- Application of MI heating cable
- Why do office buildings and other areas often use heating cables for heating?
- The benefits of installing underfloor heating cables